Applications & Sensor
| Model | AXD | 206 | 209 |
| Description | Low & high range OEM pressure transducer | Field calibration-enabled OEM pressure transducer | General purpose OEM pressure transducer |
| Sample Applications | Fuel cell OEM, Industrial OEM, CNG/LNG, Hydraulic systems, Compressor control, HVAC/R equipment |
Hydraulic systems, Compressor control, HVAC/R equipment, Tank level | Hydraulic systems, Compressor control, HVAC/R equipment, Tank level |
| Gauge (PSIG) | • | • | • |
| Sealed Gauge (PSIS) | • | • | |
| Compound (PSIC) | • | • | • |
| Absolute (PSIA) | • | ||
| Vacuum (PSIV) | • | • | |
| Ranges (PSI) | 1 to 10,000 PSIG | 25 to 10,000 PSIG | 1 to 10,000 PSIG |
| 200 to 10,000 PSIS | - | 200 to 10,000 PSIS | |
| 5 to 10,000 PSIC | 25 to 10,000 PSIC | 1 to 10,000 PSIC | |
| 25 to 5,000 PSIA | 25 to 10,000 PSIA | - | |
| ATM to 14.7 PSIV | - | ATM to 14.7 PSIV | |
| Accuracy FS (RSS) or % of reading |
±0.25% FS | ±0.13% FS | ±0.25% FS |
| Operating temperature | -40° to 257°F (-40° to 125°C) |
-40° to 185°F (-40° to 85°C) |
-40° to 185°F (-40° to 85°C) |
| Compensated temperature range | -4° to 176°F (-20 to 80°C) |
-4° to 176°F (-20 to 80°C) |
-4° to 176°F (-20 to 80°C) |
| Thermal effect % FS/100°F (% FS/50°C) |
<1% (TEB avail.) | Zero: ±1 (0.9) Span: ±1.5 (1.4) |
Zero: ±2.0 (1.8) Span: ±1.5 (1.3) |
| Media compatibility | Gases or liquid compatible with 17-4 or 316L stainless steel |
Gases or liquid compatible with 17-4 stainless steel | Gases or liquid compatible with 17-4 or 17-7 stainless steel |
| Output | 4 to 20 mA 0.5 to 5.5 VDC 0.5 to 10.5 VDC (13.5 VDC Exc. Min) 0.5 to 4.5 VDC (5 VDC Exc.) |
4 to 20 mA 0.1 to 5.1 VDC 1 to 5 VDC 1 to 6 VDC 0.1 to 10.1 VDC |
4 to 20 mA 0.5 to 5.5 VDC 1 to 5 VDC 1 to 6 VDC 0.5 to 4.5 VDC (5 VDC Exc.) |
| Electrical terminations | Cable, 3-pin Packard, M12 4-pin, 1/2” conduit |
Cable, Hirschmann, 1/2” conduit w/ cable, Terminal strip |
Cable, 3-pin Packard, 4-pin Packard, “Mini” Hirschmann, Terminal strip |
| Pressure fittings | 1/4” NPT Ext., 1/4” NPT Int., 1/8” NPT Ext., 1/8” NPT Int., 7/16” SAE, 1/4“ Int. SAE w/ Schraeder |
1/4” NPT Ext., 1/8” NPT Ext., 7/16” SAE |
1/4” NPT Ext. 7/16” SAE Ext. 1/8” NPT Ext., 1/4 Int. SAE internal 7/16”- 20 w/ Schrader, 1/2” A Ext., 1/8” NPT Int. bulkhead |
VAISALA 반도체, HVAC 적용 소개 및 기술 자료
반도체 생산 환경에서의 클린룸 습도 측정 모범 사례
스마트 환기 시스템을 통한 지속가능성 강화
바이살라 스마트 산업용 습도 측정 eGuide 다운로드
바이살라 습도 계산기
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640ㅣFAX: 031-8016-3510
견적문의: 070-4346-1844ㅣ 기술문의: hs-tech@hs-tech.co.kr
COPYRIGHT 2016 ALL RIGHT RESERVED.HS TECH Co., Ltd
HS TECH CO,. LTD
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640
FAX: 031-8016-3510
견적문의: 070-4346-1844
기술문의: hs-tech@hs-tech.co.kr
COPYRIGHT 2016 ALL RIGHT RESERVED.HS TECH Co., Ltd