정밀 계측용 차압센서
HOME > Applications & Sensor
setra
:
Applications & Sensor
| Model | ASL | 239 | 201 |
| Description | Test stand-grade low differential pressure transducer | Industry standard for high accuracy low differential pressure transducer | Very low differential/gauge pressure transducer |
| Sample Applications | Filter pressure, Leak detection systems, Exhaust pressure, Medical instrumentation, Part integrity testing, Test stands, Wind tunnels |
Leak detection systems, Exhaust pressure, Medical instrumentation, Part integrity testing, Cleanrooms (Captures dynamic pressure changes) |
Vapor recovery systems, Exhaust gas control systems ( Liquids or Gases Compatible with Stainless Steel and Inconel) |
| Ranges | 0.25 to 40” W.C. Unidirectional, ±0.1 to ±15” W.C. Bidirectional |
0.5 to 30” W.C. Unidirectional, ±0.25 to ±15” W.C. Bidirectional |
5 to 50” W.C. Unidirectional, ±2.5” to ±25” W.C. Bidirectional |
| Accuracy FS (RSS) or % of reading |
<±0.07% FS | Standard: ±0.14% FS Opt.: ±0.073% FS |
Standard: ±0.5% FS Opt.: ±0.25% FS |
| Operating temperature | -40 to 85°C | -18 to 80°C | -40 to 80°C |
| Compensated temperature range | -20 to 60°C | -1 to 65°C | -33 to 80°C |
| Thermal effect span, zero offset | Zero/Span tol. <± 0.1% FS ( 정확도 : code "A") |
Zero/Span Shift %FS/50°C: <± 0.9 |
Zero Shift %FS/°F (%FS/ºC) : <±2.0 (1.8) Span Shift %FS/°F (%FS/ºC): <±1.5 (1.4) |
| Overpressure | Operable line pressure : Vacuum to max 250 PSIG Line pressure effect : 2%/100 PSI |
Up to 45 PSI | |
| Maximum Line Pressure | 100 PSI (689,473 Pa) | ||
| Media compatibility | Clean, dry gases compatible with 300 series and 17-4 PH stainless steel | Gases compatible with stainless steel, hard adonized 6061 aluminum (Buna-N O-ring) |
Gases or liquid compatible with stainless steel and Inconel |
| Output | 0 to 5 VDC, 0 to 10 VDC, 4 to 20 mA |
4 to 20 mA, ±2.5 VDC, 0 to 5 VDC, 1 to 5 VDC, 1 to 6 VDC, 0 to 10 VDC |
4 to 20 mA |
| Electrical terminations | 3 ft (1 m) standard cable, Standard 6-pin ext. bayonet connection | Cable, 30 AWG 9-conductor cable |
1/2” NPT Ext. conduit, 4-pin bayonet connector, Hirschmann w/ large ext. fitting, Terminal strip |
| Pressure fittings | 1/8” NPT Int., Barb; 1/8” NPT Int., 1/8” NPT Int.; 1/8” NPT Ext., Barb; 7/16”-20 SAE Ext., Barb |
1/8” NPT Int. | 1/4”-18 NPT Ext., 1/4” Tube stub, 1/4”-18 NPT Int., 7/16” SAE 37° flare |
| 참고 사항 | Thermal effect accuracy Standard : ±0.5%. Opt.. : <0.25% (total error band, -20°C to 60°C) |
Vibration / Acceleration / Shock : 2g from 5 Hz to 500 Hz, 10g max, 50g operating |
Acceleration / Shock : 10g max / 50g operating |
VAISALA 반도체, HVAC 적용 소개 및 기술 자료
반도체 생산 환경에서의 클린룸 습도 측정 모범 사례
스마트 환기 시스템을 통한 지속가능성 강화
바이살라 스마트 산업용 습도 측정 eGuide 다운로드
바이살라 습도 계산기
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640ㅣFAX: 031-8016-3510
견적문의: 070-4346-1844ㅣ 기술문의: hs-tech@hs-tech.co.kr
COPYRIGHT 2016 ALL RIGHT RESERVED.HS TECH Co., Ltd
HS TECH CO,. LTD
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640
FAX: 031-8016-3510
견적문의: 070-4346-1844
기술문의: hs-tech@hs-tech.co.kr
COPYRIGHT 2016 ALL RIGHT RESERVED.HS TECH Co., Ltd