
CMS
Home > Product > CMS
DL2000
(Relative Humidity and Temperature Logger)
VAISALA's 2000 series of data loggers are designed to provide high accuracy measurements for temperature, relative humidity and an analog sensor of your choice.
DL2000
(Relative Humidity and Temperature Logger)
VAISALA's 2000 series of data loggers are designed to provide high accuracy measurements for temperature, relative humidity and an analog sensor of your choice.
■ 표
| CATEGORY | MODEL | MEASURING QUANTITY | FEATURES | APPLICATION | SPEC |
| DL2000 RH+T Logger |
DL2000-20R | CH1: T CH2: RH |
Recording span: 7.1months (Sample interval: 5 min) |
▪
Clean Room ▪ Pharmaceutical Room ▪ Laboratory ▪ Food & beverage QC ▪ Cosmetics factory |
- Measurement range: RH 10~80%RH ± 1%RH Temp -25~70℃ ± 0.1℃ - Interval: 10S~24H - Bettery Expiration Date: Maximum of 10Year - Channel: 2~4CH - Memory: 122,197-12Bit Samples - Interface: Available RS232, USB, WIFI, Ethernet - Records which meet the requirements of 21 CFR Part 11 and Annex11 can be provided. |
| DL2000-3CR | CH1: T CH2: RH CH3: 4…20mA |
Recording span: 4.7months (Sample interval: 5 min) |
|||
| DL2000-35R | CH1: T CH2: RH CH3:: 0…5VDC |
Recording span: 4.7months (Sample interval: 5 min) |
|||
| DL2000-3AR | CH1: T CH2: RH CH3: 0…10VDC |
Recording span: 4.7months (Sample interval: 5 min) |
|||
| DL2000-4BR | CH1: T CH2: RH CH3: Boolean CH4: Boolean |
Recording span: 3.5months (Sample interval: 5 min) |
| CATEGORY | MODEL | MEASURING QUANTITY | FEATURES | APPLICATION | SPEC |
|---|---|---|---|---|---|
| DL2000 RH+T Logger |
DL2000-20R | CH1: T CH2: RH |
Recording span: 7.1months(Sample interval: 5 min) | ▪ Clean Room ▪ Pharmaceutical Room ▪ Laboratory ▪ Food & beverage QC ▪ Cosmetics factory |
- Measurement range: RH 10~80%RH ± 1%RH Temp -25~70℃ ± 0.1℃ - Interval: 10S~24H - Bettery Expiration Date: Maximum of 10Year - Channel: 2~4CH - Memory: 122,197-12Bit Samples - Interface: Available RS232, USB, WIFI, Ethernet - Records which meet the requirements of 21 CFR Part 11 and Annex11 can be provided. |
| DL2000-3CR | CH1: T CH2: RH CH3: 4…20mA |
Recording span: 4.7months(Sample interval: 5 min) | |||
| DL2000-35R | CH1: T CH2: RH CH3:: 0…5VDC |
Recording span: 4.7months(Sample interval: 5 min) | |||
| DL2000-3AR | CH1: T CH2: RH CH3: 0…10VDC |
Recording span: 4.7months(Sample interval: 5 min) | |||
| DL2000-4BR | CH1: T CH2: RH CH3: Boolean CH4: Boolean |
Recording span: 3.5months(Sample interval: 5 min) |
VAISALA 반도체, HVAC 적용 소개 및 기술 자료
반도체 생산 환경에서의 클린룸 습도 측정 모범 사례
스마트 환기 시스템을 통한 지속가능성 강화
바이살라 스마트 산업용 습도 측정 eGuide 다운로드
바이살라 습도 계산기
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640ㅣFAX: 031-8016-3510
견적문의: 070-4346-1844ㅣ 기술문의: hs-tech@hs-tech.co.kr
COPYRIGHT 2016 ALL RIGHT RESERVED.HS TECH Co., Ltd
HS TECH CO,. LTD
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640
FAX: 031-8016-3510
견적문의: 070-4346-1844
기술문의: hs-tech@hs-tech.co.kr
COPYRIGHT 2016 ALL RIGHT RESERVED.HS TECH Co., Ltd